Modular aluminum-framed divider panels that separate adjacent welding stations in multi-welder departments — blocking arc flash crossover between stations, containing weld spatter within each booth, and providing welders with visual separation from neighboring operations. UV-blocking panel infill in shade 5–8, FR vinyl lower sections, and ventilation gap provisions. Portable caster-mount and fixed floor-anchor configurations to match your department layout.
Request a Quote
Weld booth dividers address a specific hazard: arc flash crossover between neighboring welding stations in open-bay welding departments. The solution must block UV and spatter while allowing fume extraction airflow and fitting the station spacing of your floor layout.
Shade 5–8 UV-blocking panels prevent arc radiation from one station from reaching adjacent welders or non-welding workers in the department — eliminating the arc eye exposure risk from neighboring stations.
Steel or heavy-gauge FR vinyl lower sections contain weld spatter within the originating station — reducing cross-contamination of adjacent work surfaces and eliminating the fire risk from spatter reaching combustible materials in neighboring booths.
Planned ventilation gaps at floor level and panel tops maintain fume extraction airflow through the department without creating direct arc flash line-of-sight between welding positions — balancing ventilation requirements with UV protection.
Divider panels are sized to match your specific station spacing, work surface height, and welding position geometry — ensuring full UV coverage from floor to above-head height without oversizing the panel system.
Caster-base versions allow full divider relocation when station layouts are reorganized. Fixed floor-anchor versions provide stable permanent separation in high-volume departments where station positions do not change.
Modular aluminum framing with consistent panel finish creates a uniform appearance across the welding department — improving workplace organization and visual management of welding zones.
Weld booth dividers from Modular Solutions are configured to the specific station layout, welding process, and ventilation requirements of your department.
Solid steel lower sections for spatter containment combined with UV-transparent upper panels for supervisor sighting lines across the department — configurable by height ratio to match your station layout.
Single-panel dividers for simple two-station separation; double-panel dividers with a gap for airflow management in high-density welding departments with multiple adjacent stations.
L-shaped and U-shaped configurations with return panels at the front and rear of the welding station for three-sided partial enclosure — increasing spatter containment without a full cell partition system.
Overhead frame extensions that continue the UV barrier above standard panel height — addressing high arc position welding (overhead welds, tall fixtures) where standard divider height is insufficient.
Arm bracket provisions and track mounting points for fume extraction arm systems integrated into the divider frame — keeping extraction arms positioned within the station without interfering with panel function.
Modular Solutions can specify and build divider systems for entire welding departments in a single engagement — consistent panel grades, frame sizes, and finishes across all stations.
Weld booth dividers are used wherever multiple welding stations occupy a shared open-bay floor space with arc flash crossover risk between positions.
Representative system parameters — all specifications are configured to your station spacing, welding process, and department layout.
A weld booth divider is a panel system installed between adjacent welding stations in a multi-welder department. Unlike a full cell partition (which encloses a single cell on all sides), a divider separates neighboring stations from each other — blocking arc flash crossover, containing weld spatter within each station, and giving welders visual privacy from adjacent operations.
Yes. Panel infill materials in weld booth dividers must resist ignition from weld spatter, which generates flying molten metal droplets. Modular Solutions uses FR-rated vinyl and steel lower panels that resist ignition at typical divider distances from the arc.
Per ANSI Z49.1, dividers protecting adjacent welders from arc flash crossover typically use shade 5–8 panels, which block UV-A and UV-B radiation without requiring the welder in the adjacent booth to wear eye protection beyond their standard PPE. Shade selection depends on arc process and distance between stations.
Yes. Ventilation gaps at floor level and at panel tops allow fume extraction airflow to move between stations and to overhead capture hoods without creating direct arc flash line-of-sight between welding positions. Modular Solutions designs ventilation provisions into divider configurations.
Yes. Modular aluminum framing with caster base options allows divider panels to be repositioned when station layouts change. Fixed floor-mount versions anchor for permanent high-volume departments. Both configurations use the same panel system for consistent department appearance.
Contact our engineering team for weld booth divider systems configured to your department layout, station spacing, and welding processes.
Request a Custom Quote