Welding Cell & Weld Screen Systems

Modular aluminum-framed welding cell partitions, UV-blocking weld screens, fire-resistant strip doors, and interlocked robotic welding cell guards — engineered to OSHA 29 CFR 1910.252 and ANSI Z49.1. Purpose-built for arc flash isolation, weld spatter containment, and fume management in manual and robotic welding environments.

Request a Quote

Welding Cell & Weld Screen Offerings

Select the system type below to explore welding protection engineered for your specific process — manual MIG/TIG, robotic arc welding, or mixed-use weld cell environments.

Cell Partitions

Welding Cell Partitions

Modular partition systems defining and isolating welding cells — UV-blocking panels, spark containment, ventilation gaps, and portable or anchored configurations.

Weld Screens

Welding Screens & UV Curtains

Shade 5–8 rigid welding screens and flexible FR vinyl UV curtains for arc flash and UV/IR radiation protection of adjacent workers. Freestanding, fixed, and overhead-track mount options.

Strip Doors

Welding Strip Doors

Fire-resistant PVC strip door systems for welding bay access — weld-grade opaque and translucent strips with hands-free entry, spark containment, and UV blocking.

Robotic Welding

Robotic Welding Guards

Interlocked perimeter guards for robotic MIG, TIG, spot, and plasma welding cells. ANSI/RIA R15.06 and OSHA 1910.252 design reference. UV curtain and fume extraction provisions included.

Custom

Custom Weld Cell Systems

Custom-engineered welding protection for hybrid cells, non-standard equipment, multi-station weld lines, and applications where standard screen and partition templates don't fit the operation.

Booth Dividers

Weld Booth Dividers

UV-blocking divider panels separating adjacent welding stations in multi-welder departments — arc flash crossover prevention, spatter containment, and ventilation gap provisions.

Fume Curtains

Weld Fume Curtain Systems

Overhead track-mounted FR vinyl curtain systems that contain the weld fume plume within the extraction capture zone — designed to work with your fume extraction equipment.

Flash Guards

Flash Guards & Grinding Curtains

FR mesh and vinyl spark curtains for grinding, cutting, and hot work operations — spark and debris containment for angle grinders, chop saws, and plasma cutters.

Welding Hazard Protection Applications

Modular Solutions engineers welding cell and weld screen systems to the specific arc process, cell configuration, and OSHA 1910.252 compliance requirements of your facility — not generic off-the-shelf panels.

Why Modular Solutions for Welding Cell Protection

Every welding protection system is engineered to the specific arc process, cell configuration, and OSHA 1910.252 compliance requirements of your facility.

ANSI Z49.1 & OSHA 1910.252 Compliance

Every welding protection system is designed to ANSI Z49.1 (Safety in Welding) and OSHA 29 CFR 1910.252 (Welding, Cutting, and Brazing). UV arc flash blocking, spatter containment, and fume extraction provisions are engineered in — not added as afterthoughts.

Shade 5–8 UV Arc Flash Protection

Welding screens and curtains are specified to ANSI/ISEA Z87.1 shade ratings appropriate to the welding process — shade 5–6 for gas welding, shade 8+ for MIG/TIG arc processes. UV and infrared radiation is blocked from adjacent personnel and surfaces.

Spark & Spatter Containment

FR-rated vinyl curtains and mesh panels contain hot spatter and spark throw within the welding zone, protecting adjacent personnel, equipment, and inventory. Material ratings specified to meet NFPA 701 flame-resistant requirements.

Fume Extraction Integration

Partitions and curtain systems are engineered with provisions for fume extraction equipment tie-in — overhead plenum connections, extraction arm ports, and curtain overlap geometry that keeps fume plumes within the extraction capture zone.

Modular & Relocatable

Partition panels, screen frames, and curtain track systems are all bolted or hooked assemblies that relocate when welding cell layouts change. No permanent facility modification required — reconfiguration takes hours, not days.

FR-Rated & Weld-Grade Materials

All curtains and vinyl strips are FR-rated (NFPA 701 tested). Screen materials are weld-grade coated. Framing is aluminum or steel selected for welding environment compatibility. No standard office partition materials are used.

Welding Cell Protection Specifications

Key engineering parameters for welding cell partition and weld screen systems.

UV Protection StandardANSI/ISEA Z87.1 shade ratings: Shade 5 for gas welding, Shade 6 for light MIG, Shade 8 for MIG/TIG/plasma. Shade level selected based on process type and proximity of adjacent personnel.
Curtain Material & Fire RatingFR PVC vinyl (standard); weld-grade mesh (spark containment); solid aluminum panels (full barrier). All curtain materials rated NFPA 701 fire-resistant. Operating temperature range −20°F to +150°F.
Compliance StandardsANSI Z49.1 (Safety in Welding); OSHA 29 CFR 1910.252 (Welding, Brazing); NFPA 701 (FR materials); ANSI/RIA R15.06 for robotic welding cell components.
Partition HeightsStandard: 5–8 ft tall. Floor-to-ceiling available. Custom heights to 14 ft for overhead crane clearance. Configurable with ceiling closure panels for maximum UV and spatter containment.
Fume Extraction IntegrationOverhead track-curtain geometry engineered to keep fume plumes within extraction capture zone. Dedicated extraction port provisions in partition panels. Compatible with all major extraction arm and overhead extraction system brands.
Gate & Access OptionsWalk-through openings with overlapping FR vinyl strips; forklift-clearance openings; interlocked safety gates for robotic welding cells; sliding FR vinyl panels for production line pass-through access.
Frame Construction6000-series aluminum extrusion for curtain tracks and partition framing; heavy-duty steel options for robotic welding perimeter guards. All hardware is stainless or hot-dip galvanized for welding environment resistance.
Lead TimeStandard weld screens and curtain sets: 1–2 weeks. Custom partition systems: 2–4 weeks. Robotic welding cell guards: 4–8 weeks from approved drawings and specification sign-off.

Frequently Asked Questions

Common questions about welding screen and partition design, OSHA compliance, and FR material ratings.

What is the OSHA requirement for welding screen protection?

OSHA 29 CFR 1910.252(b)(2) requires that workers in the vicinity of welding operations be protected from arc flash and UV radiation either by non-combustible screens, barriers, or by providing them with appropriate eye protection. ANSI Z49.1 provides detailed guidance on screen placement, shade ratings, and UV protection distances.

What shade rating do welding screens need?

Shade rating depends on the welding process and amperage. Gas welding: shade 4–6. Light MIG: shade 6–7. Heavy MIG/TIG arc: shade 8–10. Plasma cutting: shade 8–9. Screens are selected to ANSI/ISEA Z87.1 for the maximum amperage process used in the area.

Are weld screens and partitions fire-resistant?

Yes. All FR vinyl curtains and strip doors used in welding areas are rated NFPA 701 fire-resistant. The material self-extinguishes after spark or flame contact, preventing spatter from starting a larger fire. Standard PVC materials without FR rating are not used in welding environments.

Can welding partitions be reconfigured when the cell layout changes?

Yes. Modular aluminum-framed partition panels and curtain track systems use bolted connections and hook-and-loop curtain attachments — no welding or permanent anchoring. Partitions relocate, expand, or shrink as your cell layout evolves without facility modification.

How do welding curtain systems integrate with fume extraction?

Overhead track-mounted curtain systems are sized and positioned to keep the welding fume plume within the extraction equipment capture zone. Panels include extraction port provisions and can be configured with plenum connections for overhead extraction systems. The curtain layout is engineered to complement, not fight, your extraction equipment.

Specify Your Welding Protection System

Share your welding process type, cell layout, proximity of adjacent workers, and fume extraction configuration — we’ll engineer the UV-rated partition and screen system meeting your ANSI Z49.1 and OSHA requirements.

Email Us for a Quote Contact Form

Modular Solutions — 4280 Giddings Rd, Auburn Hills, MI 48326  |  248-625-1864