Modular aluminum-framed welding cell partitions, UV-blocking weld screens, fire-resistant strip doors, and interlocked robotic welding cell guards — engineered to OSHA 29 CFR 1910.252 and ANSI Z49.1. Purpose-built for arc flash isolation, weld spatter containment, and fume management in manual and robotic welding environments.
Request a Quote
Select the system type below to explore welding protection engineered for your specific process — manual MIG/TIG, robotic arc welding, or mixed-use weld cell environments.
Modular partition systems defining and isolating welding cells — UV-blocking panels, spark containment, ventilation gaps, and portable or anchored configurations.
Shade 5–8 rigid welding screens and flexible FR vinyl UV curtains for arc flash and UV/IR radiation protection of adjacent workers. Freestanding, fixed, and overhead-track mount options.
Fire-resistant PVC strip door systems for welding bay access — weld-grade opaque and translucent strips with hands-free entry, spark containment, and UV blocking.
Interlocked perimeter guards for robotic MIG, TIG, spot, and plasma welding cells. ANSI/RIA R15.06 and OSHA 1910.252 design reference. UV curtain and fume extraction provisions included.
Custom-engineered welding protection for hybrid cells, non-standard equipment, multi-station weld lines, and applications where standard screen and partition templates don't fit the operation.
UV-blocking divider panels separating adjacent welding stations in multi-welder departments — arc flash crossover prevention, spatter containment, and ventilation gap provisions.
Overhead track-mounted FR vinyl curtain systems that contain the weld fume plume within the extraction capture zone — designed to work with your fume extraction equipment.
FR mesh and vinyl spark curtains for grinding, cutting, and hot work operations — spark and debris containment for angle grinders, chop saws, and plasma cutters.
Modular Solutions engineers welding cell and weld screen systems to the specific arc process, cell configuration, and OSHA 1910.252 compliance requirements of your facility — not generic off-the-shelf panels.
Every welding protection system is engineered to the specific arc process, cell configuration, and OSHA 1910.252 compliance requirements of your facility.
Every welding protection system is designed to ANSI Z49.1 (Safety in Welding) and OSHA 29 CFR 1910.252 (Welding, Cutting, and Brazing). UV arc flash blocking, spatter containment, and fume extraction provisions are engineered in — not added as afterthoughts.
Welding screens and curtains are specified to ANSI/ISEA Z87.1 shade ratings appropriate to the welding process — shade 5–6 for gas welding, shade 8+ for MIG/TIG arc processes. UV and infrared radiation is blocked from adjacent personnel and surfaces.
FR-rated vinyl curtains and mesh panels contain hot spatter and spark throw within the welding zone, protecting adjacent personnel, equipment, and inventory. Material ratings specified to meet NFPA 701 flame-resistant requirements.
Partitions and curtain systems are engineered with provisions for fume extraction equipment tie-in — overhead plenum connections, extraction arm ports, and curtain overlap geometry that keeps fume plumes within the extraction capture zone.
Partition panels, screen frames, and curtain track systems are all bolted or hooked assemblies that relocate when welding cell layouts change. No permanent facility modification required — reconfiguration takes hours, not days.
All curtains and vinyl strips are FR-rated (NFPA 701 tested). Screen materials are weld-grade coated. Framing is aluminum or steel selected for welding environment compatibility. No standard office partition materials are used.
Key engineering parameters for welding cell partition and weld screen systems.
Common questions about welding screen and partition design, OSHA compliance, and FR material ratings.
OSHA 29 CFR 1910.252(b)(2) requires that workers in the vicinity of welding operations be protected from arc flash and UV radiation either by non-combustible screens, barriers, or by providing them with appropriate eye protection. ANSI Z49.1 provides detailed guidance on screen placement, shade ratings, and UV protection distances.
Shade rating depends on the welding process and amperage. Gas welding: shade 4–6. Light MIG: shade 6–7. Heavy MIG/TIG arc: shade 8–10. Plasma cutting: shade 8–9. Screens are selected to ANSI/ISEA Z87.1 for the maximum amperage process used in the area.
Yes. All FR vinyl curtains and strip doors used in welding areas are rated NFPA 701 fire-resistant. The material self-extinguishes after spark or flame contact, preventing spatter from starting a larger fire. Standard PVC materials without FR rating are not used in welding environments.
Yes. Modular aluminum-framed partition panels and curtain track systems use bolted connections and hook-and-loop curtain attachments — no welding or permanent anchoring. Partitions relocate, expand, or shrink as your cell layout evolves without facility modification.
Overhead track-mounted curtain systems are sized and positioned to keep the welding fume plume within the extraction equipment capture zone. Panels include extraction port provisions and can be configured with plenum connections for overhead extraction systems. The curtain layout is engineered to complement, not fight, your extraction equipment.
Share your welding process type, cell layout, proximity of adjacent workers, and fume extraction configuration — we’ll engineer the UV-rated partition and screen system meeting your ANSI Z49.1 and OSHA requirements.
Email Us for a Quote Contact FormModular Solutions — 4280 Giddings Rd, Auburn Hills, MI 48326 | 248-625-1864